Your quote Your quote

PFI-10-60

Fire-Rated Insulated Access Door with Exposed Flange

key operated cylinder cam latch, piano hinge, gasket

The fire rated insulated access door can be used on fire rated walls and ceilings. The key operated cam latch ensures a higher level of security and the gasket is used to reduce airflow between the panel and the frame.

  • Installation Walls and ceilings
  • Material Galvanneal steel
  • Locking mechanism Key operated cylinder cam latch
  • Hinge Piano hinge
  • Flange Exposed flange
  • Size Other sizes available upon request

Odd size

All dimensions respect the following order: Width X Height

Width

(inches)

Height (hinge side)

(inches)

Depth

(if applicable)

Quantity

Specifications

  • Material

    20-gauge galvanneal steel door and 16-gauge cold rolled steel frame

  • Hinge

    Continuous piano hinge. Hinge location: Hinges must be located on the second dimension (height).

  • Locking mechanism

    Key operated cylinder cam latch with 2 keys per lock

  • Flange

    1" exposed flange

  • Frame

    2½ " in depth, made of cold rolled steel

  • Rough opening

    Door sizes + ¼" or + 6mm

  • Insulation

    2" thick fire rated mineral wool

  • Inside panel release

    Mechanisms to allow panels to open from inside, standard on all doors over 12" X 12 inches.

  • Gasketing

    Neoprene around perimeter of door frame

  • Finish

    High quality white powder coat primer.

  • Packaging

    Individually wrapped, 1 door per box.

  • Fire rated access doors, for vertical use, are subject to the following:
    • Vertical wall assemblies

      Fire rated access doors, for vertical use, are subject to the following:

    • Certification

      UL 10B (2009), NFPA 252 (2012), CAN/ULC S104 (R1985), CAN/ULC S104 (2010).

    • Rating Achieved

      3 hours, neutral/negative pressure

    • Maximum size

      48" x 48" (1219mm x 1219mm), maximum area of 2304 in², tolerance on height and width limitation is more or less 3" (76mm) as long as the area does not exceed 2304 in².

    • Temperature rise

      250°F (121°C) after 30 minutes and 450°F (232°C) after 60 minutes.

  • Fire rated access doors, for horizontal use, are subject to the following:
    • Horizontal ceiling assemblies

      Fire rated access doors, for horizontal use, are subject to the following:

    • Certification

      ASTM E119 (2012), CAN/ULC S101 (2007)

    • Rating Achieved

      3 hours in non-combustible construction and 1 hour in combustible construction

    • Maximum size

      24"X36" (610 mm X 914 mm) (hinges and latches on the side of 36"), tolerance on dimension limitations are more or less 3" (76 mm) as long as the area does not exceed 864 in².

    • Temperature rise

      Within allowable per ASTM E119 and CAN/ULC S101

Dimensions

Dimensions (Inches)Dimensions (Millimeters)Weight (LBS)Weight (KG)Number of locks
* 8 x 8203 x 2036.93.11
* 10 x 10254 x 2548.94.01
* 12 x 12304 x 30411.35.11
* 14 x 14355 x 35513.76.21
* 16 x 16406 x 40616.17.31
* 18 x 18457 x 45719.08.61
* 22 x 22558 x 55825.611.61
* 22 x 30558 x 76232.214.61
* 22 x 36558 x 91438.517.52
* 24 x 24609 x 60928.913.11
* 24 x 36609 x 91440.818.52
* 24 x 48609 x 121950.522.92
* 30 x 30762 x 76240.818.51
* 32 x 32812 x 81245.820.82
* 36 x 36914 x 91454.724.82
* 48 x 481219 x 121984.938.52
* If door size exceeds 24" X 36", the latter is not fire-rated for ceiling installation. All dimensions are written in the following order: Width X Height

Technical drawings